Containerized Load Bank 3mva 4mva 5mva Resistive Inductive Loadbank for Power Grid/Data Center/Generator Test

Product Details
Warranty: 12 Months
Max Diameter of Workpiece: 1200mm
Mass Scope of Workpiece: <900kg
Diamond Member Since 2025

Suppliers with verified business licenses

Main Products
Diesel Engine, Load Bank, Marine Generator, LPG/Ng Generator, Diesel Generator
Year of Establishment
2018-06-27
Address
Room 11, 10th Floor, Building A1#, Cangshan Wanda Plaza, No. 272, Pushang Avenue, Jinshan ...
  • Containerized Load Bank 3mva 4mva 5mva Resistive Inductive Loadbank for Power Grid/Data Center/Generator Test
  • Containerized Load Bank 3mva 4mva 5mva Resistive Inductive Loadbank for Power Grid/Data Center/Generator Test
  • Containerized Load Bank 3mva 4mva 5mva Resistive Inductive Loadbank for Power Grid/Data Center/Generator Test
  • Containerized Load Bank 3mva 4mva 5mva Resistive Inductive Loadbank for Power Grid/Data Center/Generator Test
  • Containerized Load Bank 3mva 4mva 5mva Resistive Inductive Loadbank for Power Grid/Data Center/Generator Test
  • Containerized Load Bank 3mva 4mva 5mva Resistive Inductive Loadbank for Power Grid/Data Center/Generator Test
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • Workshop
  • Packaging & Shipping
  • Exhibition
  • FAQ
Overview

Basic Info.

Model NO.
MC
Type
Universal Testing Machine
Maxcapacity
Power Loading Test
Accuracy Grade
1
Load Way
Electronic Load
Loading Method
Static Load
Display
Digital
Control
Computer Control
Weight
0-100Kg
Power Source
110-480V
Oil Cylinder Position
Test Machine
Protection
Over-Temperature, Over-Current, Short Circuit
Adjustment
1kw
Control Method
Manual/Automatic
Cooling
Forced Air Cooling, Horizontal Inlet Air and Horiz
Application
Data Center/Generator Testing/Power Grid
Load Tolerance (Each Step)
Plus or Minus 5% 3%
Containerized Type
Outdoor Use/Weather Proof
Mecca Load Bank
5kw-6000kw
Control Model
Intelligent Control/PC Control/Remote Control
Power Factor 0.8 Lagging
Resistive Inductive Load Bank
Transport Package
Plywood Package
Specification
35kg
Trademark
MECCA
Origin
China
HS Code
903033
Production Capacity
1000/Year

Product Description

MECCA POWER LOAD BANK 5KW-6000KW
Resistive Load Bank
With a wealth of load bank equipment solutions backed by exceptional service, Mecca Power Solutions service offering keeps us way ahead of the competition.  
With facilities covering worldwide, we offer competitive and reliable load bank solutions on time and on budget.  The load bank engineers can install the load bank equipment and provide full documentation and easy to interpret results.
Resistive /Reactive Load Bank
Resistive Reactive Load Bank is the perfect solution for regularly scheduled maintenance testing and commissioning of mission-critical standby emergency power systems where rated kVA, rated power factor and rated current testing is required.
High Voltage Load Bank
The ability to test critical power systems at voltages of 1.2KV to 80kV using direct-connect, High Voltage Load Bank offers engineers flexibility, time savings, cost savings, space savings and simplicity.
Portable LOAD BANK
Light, powerful and easy to handle, it is the ideal partner for the experts of the power generator: maintainers, rental companies...
Use our load bank to test:Diesel generators
DC generators and power supplies
Rectifiers
Data Centre Power and Thermal Systems
Uninterrupted Power Systems (UPS)
Motors (starting systems)
Rack Mount Load Bank
Rack Mounted Load Banks is designed to perform safe load tests of entire Data Center systems, including power generators, UPS systems and ventilation and air conditioning (HVAC) installations.
Containerized Load Bank 3mva 4mva 5mva Resistive Inductive Loadbank for Power Grid/Data Center/Generator Test
Product Description
Containerized Load Bank 3mva 4mva 5mva Resistive Inductive Loadbank for Power Grid/Data Center/Generator Test
Containerized Load Bank 3mva 4mva 5mva Resistive Inductive Loadbank for Power Grid/Data Center/Generator Test
Containerized Load Bank 3mva 4mva 5mva Resistive Inductive Loadbank for Power Grid/Data Center/Generator Test
Containerized Load Bank 3mva 4mva 5mva Resistive Inductive Loadbank for Power Grid/Data Center/Generator Test
Containerized Load Bank 3mva 4mva 5mva Resistive Inductive Loadbank for Power Grid/Data Center/Generator Test
Containerized Load Bank 3mva 4mva 5mva Resistive Inductive Loadbank for Power Grid/Data Center/Generator Test
Containerized Load Bank 3mva 4mva 5mva Resistive Inductive Loadbank for Power Grid/Data Center/Generator Test
Containerized Load Bank 3mva 4mva 5mva Resistive Inductive Loadbank for Power Grid/Data Center/Generator Test
Specification
RESISTIVE LOAD BANK                                                                                                                            50/60HZ  100-3000KW
Model
Rated Power
Power Factor
Load Voltage
Dimension
Weight
(L*W*H)mm
(kg)
MCLB-100
100kW
1.0
3PH 380-480V
(380V,400V,415V,440V,460V,480V
OPTIONAL)
540*292*604
35
MCLB-200
200kW
750*511*746
95
MCLB-200
200kW
748*517*726
85
MCLB-250
250kW
1440*1300*1070
550
MCLB-500
500kW
1100*900*1200
385
MCLB-500
500kW
1800*1300*1070
700
MCLB-600
600kW
1800*1420*1190
800
MCLB-1000
1000kW
1800*1300*1918
1300
MCLB-1250
1250kW
2660*1600*2100
2000
MCLB-1500
1500kW
2400*1700*1800
1700
MCLB-2000
2000kW
4000*2100*2100
4500
MCLB-2500
2500kW
6058*2438*2591
7500
MCLB-3000
3000kW
6058*2438*2591
8000
RESISTIVE INDUCTIVE LOAD BANK                               50/60HZ                                 40KW-4800KW
Model
Installed Capacity
Power Factor
Load Voltage
Dimension
Weight
W*D*H(mm)
(kg)
MCLB-40
R: 40kW
0.8/1.0
3PH 380-480V
(380V,400V,415V,440V,460V,480V
OPTIONAL)
1200*900*1350
150
L: 30kVAr
MCLB-100
R: 100kW
1860*1100*1450
375
L: 75kVAr
MCLB-800
R: 800kW
R:2440*1400*1680
3000
L: 600kVAr
L:2440*1400*1680
MCLB-1200
R: 1200kW
6058*2438*2591
4500
L: 900kVAr
MCLB-1600
R: 1600kW
6058*2438*2591
6000
L: 1200kVAr
MCLB-2000
R: 2000kW
6058*2438*2591
7500
L: 1500kVAr
MCLB-2400
R: 2400kW
6058*2438*2591
9000
L: 1800kVAr
MCLB-2800
R: 2800kW
6058*2438*2591
10500
L: 2100kVAr
MCLB-3500
R: 3500kW
6058*2438*2591
13125
L: 2625kVAr
MCLB-4000
R: 4000kW
12192*2438*2591
15000
L: 3000kVAr
MCLB-4800
R: 4800kW
12192*2438*2591
18000
L: 3600kVAr
HIGH VOLTAGE LOAD BANK                                           50/60HZ                                2000KW-6000KW
Model
Installed Capacity
Power Factor
Load Voltage
Dimension
Weight(kg)
W*D*H(mm)
MCLB-2000kW
2000kW
1
3 phase 3.3-11KV 50/60Hz
6058*2438*2591
6000
MCLB-3000kW
3000kW
6058*2438*2591
7000
MCLB-5000kW
5000kW
12192*2438*2591
140000
MCLB-6000kW
6000kW
12192*2438*2591
160000
The parameters is only for reference, pls contact us for exact information
Note: The dimension and weight vary with different load bank design and different load step requirements.   
Workshop
Containerized Load Bank 3mva 4mva 5mva Resistive Inductive Loadbank for Power Grid/Data Center/Generator Test
Containerized Load Bank 3mva 4mva 5mva Resistive Inductive Loadbank for Power Grid/Data Center/Generator Test
Packaging & Shipping
Containerized Load Bank 3mva 4mva 5mva Resistive Inductive Loadbank for Power Grid/Data Center/Generator Test
Exhibition
Containerized Load Bank 3mva 4mva 5mva Resistive Inductive Loadbank for Power Grid/Data Center/Generator Test
Containerized Load Bank 3mva 4mva 5mva Resistive Inductive Loadbank for Power Grid/Data Center/Generator Test
Containerized Load Bank 3mva 4mva 5mva Resistive Inductive Loadbank for Power Grid/Data Center/Generator Test
FAQ
1.Q: What is your MOQ of this item?
A:1 Set
2.Q: What are your payment terms?
A:30% TT as deposit,70% TT before Shipment or 100% LC at sight
3.Q:What's the warranty time of diesel generators?
A:Global Warranty: 12months after delivery or 1000 running hours, whichever come first.
4.Q:Can you accept the customized products?
A:Yes, of course.We accept your specific order if you can provide us your special requirements or special samples
5.Q:What's the delivery time ?
A:20 to 35 days after receiving your payment in advance.
6.Q:Do you offer OEM service?
A: Yes
7.Q:What is the power range do you have?
A:Mecca Power assemble genset from 2 to 4000kva
8.Q:What's your special compare to other manufacturer? 